A) Combustion, smoke, flame B) Fuel, air, ignition C) Heat, fuel, chemical chain reaction D) Oxygen, fuel, heat
A) Oxygen B) Heat C) Chemical chain reaction D) Fuel
A) Heat energy B) Carbon dioxide C) Water vapor D) Carbon monoxide
A) Internal chemical reaction B) Sunlight C) Open flame D) Electrical sparks
A) Direct molecular contact B) Convection currents C) Fluid movement D) Electromagnetic waves
A) Fire suppression B) Fluid movement C) Radiation from fire D) Molecular vibrations
A) Incipient B) Growth C) Fully developed D) Decay
A) Ventilation control B) Letting it burn C) Portable extinguisher D) Fire department only
A) Spontaneous heating B) All of the above C) Friction D) Solar heat
A) Smoke B) Flame C) Water only D) Heat, fuel, oxygen, or chain reaction
A) Flammable liquids B) Metals C) Ordinary combustibles D) Electrical equipment
A) Eliminating ignition sources B) Rescue C) Controlling smoke D) Extinguishing after ignition
A) Observe pattern B) Post-fire investigation C) Confine and extinguish fire D) Let it burn safely
A) Heat B) Any of the above C) Oxygen D) Fuel
A) Sprinklers B) Fire alarms C) Smoke detectors D) Fire-resistant walls and doors
A) Decay, foam B) Fire-resistant walls and doors C) Fully developed, water hose D) Growth stage, portable extinguisher
A) Spontaneous combustion B) Flashover C) Complete combustion D) Incomplete combustion
A) Convection B) Combustion C) Conduction D) Radiation
A) Fuel B) Heat C) Oxygen D) Chain reaction
A) Conduction B) Radiation C) Combustion D) Convection
A) Decay B) Growth C) Fully developed D) Incipient
A) Remove fuel B) Remove heat C) Disrupt chain reaction D) Remove oxygen
A) Mechanical B) Electrical C) Solar D) Chemical
A) Conduction B) Diffusion C) Radiation D) Convection
A) Decay B) Incipient C) Growth D) Fully developed
A) Qualified B) Accidental C) Malicious D) Negligent
A) Accidental fire B) Qualified arson C) Malicious arson D) Negligent arson
A) Qualified arson B) Accidental C) Negligent fire D) Simple arson
A) Special aggravating circumstance B) Not an aggravating circumstance C) A qualifying circumstance D) generic aggravating circumstance
A) CO₂ B) Dry powder C) Foam D) Water
A) Remove fuel B) Interrupt chain reaction C) Remove oxygen D) Remove heat
A) Overhaul B) Rescue C) Exposure protection D) Suppression
A) Cooling B) Starvation C) Smothering D) Chain reaction interruption
A) Suppression B) Prevention C) Overhaul D) Investigation
A) Rescue B) Overhaul C) Exposure protection and suppression D) Investigation
A) Cloth B) Dry powder C) Water D) Foam
A) Rescue B) Suppression C) Prevention D) Overhaul
A) Administrative control B) Engineering control C) Overhaul D) PPE
A) Smothering; Rescue & Suppression B) Starvation; Prevention C) Chain reaction disruption; Overhaul D) Cooling; Rescue
A) Cool fire B) Avoid water damage while displacing oxygen C) Remove fuel D) Overhaul
A) Rescue B) Suppression & exposure protection C) Overhaul D) Prevention
A) Prevention B) Fireground management during suppression C) Overhaul D) Rescue only
A) Smothering B) Interrupt chain reaction C) Removing fuel D) Cooling
A) Water application B) Smothering C) Cooling D) Chain reaction interruption
A) Fire classification B) Rescue C) Suppression methods D) Determine fire origin
A) Electrical fire B) Accelerants C) Suppression error D) Point of origin at bottom of V
A) High B) Explosion C) Accidental D) Floor level
A) Arson B) Spontaneous combustion C) Electrical fire D) Accidental fire
A) Rescue B) Age building C) Identify fire origin & cause D) Suppression efficiency
A) Electrical fault B) Arson excluded C) Fire started at single point D) Multiple points
A) Intentional fire (arson) B) Single accidental fire C) Electrical fire D) Standard growth
A) Fire spread influenced by air movement B) Fire suppressed quickly C) Passive failure D) Fire started at ceiling
A) Standard suppression B) Accidental fire at center C) Electrical fire D) Accelerants in corners
A) Multiple origin (arson) B) Accidental fire C) Electrical origin D) Single source
A) Passive efficiency B) Age C) Fire intensity & spread D) Soot removal
A) Fire-resistant walls B) Sprinklers C) Sensors or devices D) Passive alarms
A) Passive detection B) Alarm only C) Active detection D) Suppression
A) Active detection B) Alarm components C) Passive protection D) Sprinklers
A) Contain fuel B) Suppress fire C) Detect smoke & trigger alarm D) Ventilate smoke
A) Sprinkler suppression B) Fireproof barrier C) Active detection & alarm D) Passive detection
A) Alarm only B) Overhaul tool C) Active detection & suppression D) Passive protection
A) Electrical fire B) Spontaneous fire C) Intentional/arson D) Accidental
A) Active suppression support B) Passive barrier C) Detection D) Alarm system
A) Overhaul B) Active detection C) Passive detection D) Alarm only
A) Rescue operations B) Malice, fire, property damage C) Negligence D) Only fire & damage
A) Simple negligence B) Passive failure C) Suppression act D) Qualified arson
A) Negligent fire B) Qualified arson with aggravation C) Passive failure D) Simple arson
A) Negligent fire B) Passive violation C) Simple fire D) Malicious/qualified
A) Fire extinguished B) Own property C) Nighttime fire D) Unoccupied building
A) Standard growth B) Single accidental C) Electrical D) Multiple ignition points
A) Accidental B) Negligence C) Arson D) Passive failure
A) Fire intensity & duration B) Suppression C) Building age D) Ownership
A) Property value B) Overhaul C) Fire age D) Fire path & movement
A) Fire origin near floor B) Accelerants C) Suppression effective D) Passive failure
A) Likely arson B) Electrical C) Accidental D) Suppression error
A) Time of day only B) Alarm presence C) Financial loss only D) Intent, property type, risk to life
A) Negligent B) Prevention violation C) Accidental D) Qualified due to fraud & malice
A) Fire department arrival B) Detection time C) Malicious intent & accelerants D) Fire extinguishers
A) Time & risk to human life B) Sprinkler presence C) Property value D) Department arrival
A) Sprinkler efficiency B) Detection only C) Malice, risk, property damage D) Passive protection
A) Passive failure B) Negligent C) Suppression oversight D) Malicious arson
A) Penalty B) Suppression C) Reduces penalty D) Irrelevant
A) Point of origin B) Accelerants C) Random D) Electrical fault
A) Air-influenced fire spread B) Fire started at floor C) Point of origin D) Electrical fault
A) Soot removal B) Wood age C) Fire intensity & spread D) Passive efficiency
A) Electrical fire only B) Multiple ignition sources indicating possible arson C) Accidental fire D) Passive protection failure
A) Electrical short B) Standard fire growth C) Intentional ignition using accelerants D) Spontaneous fire
A) Overhaul procedure B) Passive protection success C) Accidental fire D) Use of accelerants to intentionally spread fire
A) Electrical fault B) Single accidental origin C) Multiple intentional points of origin D) Standard flame progression
A) Passive protection B) Fire spread influenced by ventilation C) Fire started at roof D) Electrical short only
A) Fire suppression success B) Passive protection breach C) Fire origin near floor D) Electrical origin only
A) Electrical short B) Spontaneous combustion C) Malicious arson with multiple ignition points D) Accidental fire
A) Negligent fire B) Electrical fault C) Intentional arson D) Passive detection failure
A) Fire extinguisher placement B) Building age C) Fire origin only D) Fire intensity and movement
A) Negligent fire B) Fire spread influenced by air currents C) Passive protection failure D) Fire origin near ceiling
A) Possible deliberate ignition with accelerants B) Fire suppressed too early C) Single accidental fire D) Fireproofing failure
A) Passive protection violation B) Arson using accelerants C) Accidental spill fire D) Electrical fire
A) Multiple intentional ignition points B) Fire spread naturally C) Single accidental origin D) Passive protection success
A) Electrical origin B) Standard growth C) Overhaul stage only D) Potential arson with accelerants
A) Electrical short B) Negligent fire C) Fire suppression error D) Malicious arson |