  • 1. The fire triangle consists of?
A) Combustion, smoke, flame
B) Fuel, air, ignition
C) Heat, fuel, chemical chain reaction
D) Oxygen, fuel, heat
  • 2. The fire tetrahedron differs from the fire triangle by including?
A) Oxygen
B) Heat
C) Chemical chain reaction
D) Fuel
  • 3. Which is not a product of complete combustion?
A) Heat energy
B) Carbon dioxide
C) Water vapor
D) Carbon monoxide
  • 4. Primary source of heat in spontaneous combustion?
A) Internal chemical reaction
B) Sunlight
C) Open flame
D) Electrical sparks
  • 5. Conduction transfers heat through?
A) Direct molecular contact
B) Convection currents
C) Fluid movement
D) Electromagnetic waves
  • 6. Convection transfers heat by?
A) Fire suppression
B) Fluid movement
C) Radiation from fire
D) Molecular vibrations
  • 7. Stage of fire with rapid spread and full involvement of materials?
A) Incipient
B) Growth
C) Fully developed
D) Decay
  • 8. A fire in the incipient stage is best controlled by?
A) Ventilation control
B) Letting it burn
C) Portable extinguisher
D) Fire department only
  • 9. Primary sources of ignition include?
A) Spontaneous heating
B) All of the above
C) Friction
D) Solar heat
  • 10. The tetrahedron model emphasizes suppression by removing?
A) Smoke
B) Flame
C) Water only
D) Heat, fuel, oxygen, or chain reaction
  • 11. Class A fire involve?
A) Flammable liquids
B) Metals
C) Ordinary combustibles
D) Electrical equipment
  • 12. Fire prevention focuses on?
A) Eliminating ignition sources
B) Rescue
C) Controlling smoke
D) Extinguishing after ignition
  • 13. Primary goal of fire suppression?
A) Observe pattern
B) Post-fire investigation
C) Confine and extinguish fire
D) Let it burn safely
  • 14. Fire triangle element that can be removed to extinguish fire?
A) Heat
B) Any of the above
C) Oxygen
D) Fuel
  • 15. Passive fire protection includes?
A) Sprinklers
B) Fire alarms
C) Smoke detectors
D) Fire-resistant walls and doors
  • 16. Small fire in trash can, appropriate action?
A) Decay, foam
B) Fire-resistant walls and doors
C) Fully developed, water hose
D) Growth stage, portable extinguisher
  • 17. Black smoke and incomplete combustion products indicate?
A) Spontaneous combustion
B) Flashover
C) Complete combustion
D) Incomplete combustion
  • 18. Heat transferring via direct contact to nearby metal beam demonstrates?
A) Convection
B) Combustion
C) Conduction
D) Radiation
  • 19. Multiple ignition sources suggest manipulation of which fire tetrahedron element?
A) Fuel
B) Heat
C) Oxygen
D) Chain reaction
  • 20. Hot gases rising in a room illustrate?
A) Conduction
B) Radiation
C) Combustion
D) Convection
  • 21. Heat damage patterns suggest which fire stage?
A) Decay
B) Growth
C) Fully developed
D) Incipient
  • 22. Removing oxygen to extinguish a fire demonstrates?
A) Remove fuel
B) Remove heat
C) Disrupt chain reaction
D) Remove oxygen
  • 23. Electrical short circuit causes fire; heat source is?
A) Mechanical
B) Electrical
C) Solar
D) Chemical
  • 24. Heat radiating across room without contact is?
A) Conduction
B) Diffusion
C) Radiation
D) Convection
  • 25. Flashover occurs in which stage?
A) Decay
B) Incipient
C) Growth
D) Fully developed
  • 26. Homeowner leaves stove on; fire occurs. Type of arson?
A) Qualified
B) Accidental
C) Malicious
D) Negligent
  • 27. Intentionally burning neighbor’s warehouse is?
A) Accidental fire
B) Qualified arson
C) Malicious arson
D) Negligent arson
  • 28. Fire caused to commit insurance fraud is?
A) Qualified arson
B) Accidental
C) Negligent fire
D) Simple arson
  • 29. Aggravating factor under PD 1613: Fire occurs at night
A) Special aggravating circumstance
B) Not an aggravating circumstance
C) A qualifying circumstance
D) generic aggravating circumstance
  • 30. Small electrical fire in transformer; extinguisher?
A) CO₂
B) Dry powder
C) Foam
D) Water
  • 31. Shutting off fuel supply during fire represents?
A) Remove fuel
B) Interrupt chain reaction
C) Remove oxygen
D) Remove heat
  • 32. Ventilation of smoke in structure fire is part of?
A) Overhaul
B) Rescue
C) Exposure protection
D) Suppression
  • 33. Dry powder used to interrupt chemical reaction is?
A) Cooling
B) Starvation
C) Smothering
D) Chain reaction interruption
  • 34. Fire drills and training represent?
A) Suppression
B) Prevention
C) Overhaul
D) Investigation
  • 35. Hose application to limit warehouse fire spread is part of?
A) Rescue
B) Overhaul
C) Exposure protection and suppression
D) Investigation
  • 36. Class D fire in metal factory; extinguishing strategy?
A) Cloth
B) Dry powder
C) Water
D) Foam
  • 37. Cooling embers after fire is part of?
A) Rescue
B) Suppression
C) Prevention
D) Overhaul
  • 38. Removing flammable chemicals in lab is?
A) Administrative control
B) Engineering control
C) Overhaul
D) PPE
  • 39. Foam applied to flammable liquid spill while evacuating people combines?
A) Smothering; Rescue & Suppression
B) Starvation; Prevention
C) Chain reaction disruption; Overhaul
D) Cooling; Rescue
  • 40. CO₂ extinguisher in computer server room used to?
A) Cool fire
B) Avoid water damage while displacing oxygen
C) Remove fuel
D) Overhaul
  • 41. Water lines to protect exposures illustrate?
A) Rescue
B) Suppression & exposure protection
C) Overhaul
D) Prevention
  • 42. Coordinated firefighting teams demonstrate?
A) Prevention
B) Fireground management during suppression
C) Overhaul
D) Rescue only
  • 43. Removing gasoline spill fire by taking unignited fuel?
A) Smothering
B) Interrupt chain reaction
C) Removing fuel
D) Cooling
  • 44. Covering oil-soaked rags with metal lid is?
A) Water application
B) Smothering
C) Cooling
D) Chain reaction interruption
  • 45. Heat and flame patterns near doorway help to?
A) Fire classification
B) Rescue
C) Suppression methods
D) Determine fire origin
  • 46. V-shaped burn pattern indicates?
A) Electrical fire
B) Accelerants
C) Suppression error
D) Point of origin at bottom of V
  • 47. Heavy ceiling fire, furniture intact; fire started?
A) High
B) Explosion
C) Accidental
D) Floor level
  • 48. Irregular burn and accelerant residues suggest?
A) Arson
B) Spontaneous combustion
C) Electrical fire
D) Accidental fire
  • 49. Soot distribution analysis used to?
A) Rescue
B) Age building
C) Identify fire origin & cause
D) Suppression efficiency
  • 50. Burn patterns spreading outward from center indicate?
A) Electrical fault
B) Arson excluded
C) Fire started at single point
D) Multiple points
  • 51. Multiple ignition sources suggest?
A) Intentional fire (arson)
B) Single accidental fire
C) Electrical fire
D) Standard growth
  • 52. Smoke swirling along ventilation paths indicates?
A) Fire spread influenced by air movement
B) Fire suppressed quickly
C) Passive failure
D) Fire started at ceiling
  • 53. Corners burned, center lightly charred suggest?
A) Standard suppression
B) Accidental fire at center
C) Electrical fire
D) Accelerants in corners
  • 54. Irregular charring at multiple entries suggests?
A) Multiple origin (arson)
B) Accidental fire
C) Electrical origin
D) Single source
  • 55. Alligatoring on wood indicates?
A) Passive efficiency
B) Age
C) Fire intensity & spread
D) Soot removal
  • 56. Active detection requires?
A) Fire-resistant walls
B) Sprinklers
C) Sensors or devices
D) Passive alarms
  • 57. Smoke detectors are?
A) Passive detection
B) Alarm only
C) Active detection
D) Suppression
  • 58. Fire-rated walls are?
A) Active detection
B) Alarm components
C) Passive protection
D) Sprinklers
  • 59. Fire alarm control panel functions to?
A) Contain fuel
B) Suppress fire
C) Detect smoke & trigger alarm
D) Ventilate smoke
  • 60. Manual pull stations activate?
A) Sprinkler suppression
B) Fireproof barrier
C) Active detection & alarm
D) Passive detection
  • 61. Sprinkler with heat sensor?
A) Alarm only
B) Overhaul tool
C) Active detection & suppression
D) Passive protection
  • 62. Multiple points of origin indicate?
A) Electrical fire
B) Spontaneous fire
C) Intentional/arson
D) Accidental
  • 63. Standpipe system is?
A) Active suppression support
B) Passive barrier
C) Detection
D) Alarm system
  • 64. Flame detector in storage?
A) Overhaul
B) Active detection
C) Passive detection
D) Alarm only
  • 65. Arson requires?
A) Rescue operations
B) Malice, fire, property damage
C) Negligence
D) Only fire & damage
  • 66. Fire set to intimidate workers?
A) Simple negligence
B) Passive failure
C) Suppression act
D) Qualified arson
  • 67. Explosive material fire classification?
A) Negligent fire
B) Qualified arson with aggravation
C) Passive failure
D) Simple arson
  • 68. Arson with insurance fraud is?
A) Negligent fire
B) Passive violation
C) Simple fire
D) Malicious/qualified
  • 69. Aggravating factors include?
A) Fire extinguished
B) Own property
C) Nighttime fire
D) Unoccupied building
  • 70. Multiple V-patterns in rooms suggest?
A) Standard growth
B) Single accidental
C) Electrical
D) Multiple ignition points
  • 71. Accelerants and irregular burn patterns suggest?
A) Accidental
B) Negligence
C) Arson
D) Passive failure
  • 72. Char depth analysis estimates?
A) Fire intensity & duration
B) Suppression
C) Building age
D) Ownership
  • 73. Smoke residue on ceiling traces?
A) Property value
B) Overhaul
C) Fire age
D) Fire path & movement
  • 74. Rapid charring on floorboards indicates?
A) Fire origin near floor
B) Accelerants
C) Suppression effective
D) Passive failure
  • 75. Fire scene with multiple points of origin & entries?
A) Likely arson
B) Electrical
C) Accidental
D) Suppression error
  • 76. Malicious arson evaluation considers?
A) Time of day only
B) Alarm presence
C) Financial loss only
D) Intent, property type, risk to life
  • 77. Arson for tax evasion is?
A) Negligent
B) Prevention violation
C) Accidental
D) Qualified due to fraud & malice
  • 78. Differentiating arson vs accidental?
A) Fire department arrival
B) Detection time
C) Malicious intent & accelerants
D) Fire extinguishers
  • 79. Fire set at night in multi-unit building?
A) Time & risk to human life
B) Sprinkler presence
C) Property value
D) Department arrival
  • 80. Fire intentionally set in school; investigators focus on?
A) Sprinkler efficiency
B) Detection only
C) Malice, risk, property damage
D) Passive protection
  • 81. Torch used to ignite neighbor’s house?
A) Passive failure
B) Negligent
C) Suppression oversight
D) Malicious arson
  • 82. Use of flammable liquids aggravates?
A) Penalty
B) Suppression
C) Reduces penalty
D) Irrelevant
  • 83. Burn patterns concentrated in doorway?
A) Point of origin
B) Accelerants
C) Random
D) Electrical fault
  • 84. Irregular burn near ceiling vent indicates?
A) Air-influenced fire spread
B) Fire started at floor
C) Point of origin
D) Electrical fault
  • 85. Alligatoring on wooden surfaces helps analyze?
A) Soot removal
B) Wood age
C) Fire intensity & spread
D) Passive efficiency
  • 86. Investigators find burn patterns leading to multiple disconnected points. This suggests?
A) Electrical fire only
B) Multiple ignition sources indicating possible arson
C) Accidental fire
D) Passive protection failure
  • 87. Heavy charring near flammable chemical containers indicates?
A) Electrical short
B) Standard fire growth
C) Intentional ignition using accelerants
D) Spontaneous fire
  • 88. Fire spreading faster along flammable liquid trails suggests?
A) Overhaul procedure
B) Passive protection success
C) Accidental fire
D) Use of accelerants to intentionally spread fire
  • 89. V-patterns leading to multiple walls indicate?
A) Electrical fault
B) Single accidental origin
C) Multiple intentional points of origin
D) Standard flame progression
  • 90. Burn pattern analysis in a warehouse shows fire intensifying near doors and windows. This could indicate?
A) Passive protection
B) Fire spread influenced by ventilation
C) Fire started at roof
D) Electrical short only
  • 91. Charring on floorboards with minimal ceiling damage helps determine?
A) Fire suppression success
B) Passive protection breach
C) Fire origin near floor
D) Electrical origin only
  • 92. Irregular alligatoring and deep char in multiple rooms suggests?
A) Electrical short
B) Spontaneous combustion
C) Malicious arson with multiple ignition points
D) Accidental fire
  • 93. Accelerant residue found at several points in a building supports?
A) Negligent fire
B) Electrical fault
C) Intentional arson
D) Passive detection failure
  • 94. Burn patterns in a stairwell indicate rapid vertical fire spread. This analysis helps investigators determine?
A) Fire extinguisher placement
B) Building age
C) Fire origin only
D) Fire intensity and movement
  • 95. Smoke staining on ceiling beams, concentrated near vent openings, suggests?
A) Negligent fire
B) Fire spread influenced by air currents
C) Passive protection failure
D) Fire origin near ceiling
  • 96. Multiple points of heavy charring near electrical panels and doorways indicate?
A) Possible deliberate ignition with accelerants
B) Fire suppressed too early
C) Single accidental fire
D) Fireproofing failure
  • 97. Burn patterns radiating from overturned containers of flammable liquid indicate?
A) Passive protection violation
B) Arson using accelerants
C) Accidental spill fire
D) Electrical fire
  • 98. “U-shaped” char patterns on walls and furniture suggest?
A) Multiple intentional ignition points
B) Fire spread naturally
C) Single accidental origin
D) Passive protection success
  • 99. Rapid fire spread in interconnected rooms, unusual charring on supporting beams, indicates?
A) Electrical origin
B) Standard growth
C) Overhaul stage only
D) Potential arson with accelerants
  • 100. Investigators conclude that unusual burn patterns, multiple points of origin, and accelerant residue together suggest?
A) Electrical short
B) Negligent fire
C) Fire suppression error
D) Malicious arson